Before natural gas can be liquefied, moisture and certain heavy hydrocarbons may need to be removed from the feed gas. Left untreated, these impurities can cause freeze-ups in process equipment and put cryogenic heat exchangers at risk. PSB Industries designs skid-mounted LNG gas treatment systems that use molecular-sieve-based temperature swing adsorption (TSA) technology for dehydration, heavy hydrocarbon removal or both.
Protecting LNG Equipment Through Dehydration
Water in natural gas can form ice and hydrates during LNG processing, blocking equipment and contributing to freeze-ups in valves and instrumentation. It can also put cryogenic heat exchangers and cold boxes at risk. PSB’s gas dehydration systems remove water before liquefaction to help operators meet stringent outlet-water requirements and reduce moisture-related operational problems.
PSB custom designs its skid-mounted dehydration systems with single- to multi-layered-bed configurations to accommodate varying process conditions and provide ease of on-site installation. The stated design ranges are:
- Flow: 1 to 200 MMSCFD
- Pressure: 150 to 1,450 psig
- Temperature: 50 to 122°F
- Outlet water content: Less than 1 ppmv, with a dew point below −100°C (−148°F)
How PSB’s TSA Systems Operate
PSB’s LNG dehydration systems are automatic and heat regenerative. They use dry product gas for regeneration, with either an electric or gas-fired heater as the heat source. An air cooler or shell-and-tube heat exchanger can cool the gas, and PSB can provide heat-integration options with upstream or downstream compression to help optimize operating costs.
The dehydration systems operate in a closed loop with zero gas emissions or gas losses for water removal. High-efficiency coalescing and particulate filters upstream and downstream of the TSA vessels protect the adsorbent media from aerosols and downstream equipment from dust and particulates.
Removing Heavy Hydrocarbons Before Liquefaction
For feed-gas streams that require heavy hydrocarbon (HHC) removal, PSB offers skid-mounted TSA systems designed to remove C6+, naphthalene, benzene and toluene. Removing these contaminants helps address the risk of freeze-up in downstream liquefaction trains and plate-and-fin heat exchangers, as well as off-spec product gas in some cases.
These systems are designed for small-scale and peak-shaving LNG plants. The stated design ranges are:
- Flow: 1 to 100 MMSCFD
- Pressure: 430 to 1,200 psig
- Temperature: 50 to 122°F
Depending on the system design, regeneration can take place in an open, semi-closed or closed loop. For small-scale LNG plants or LNG peak-shaving facilities facing budget and space constraints, these skid-mounted systems offer a highly cost-effective, minimal-footprint option.
Combining Dehydration and HHC Removal
When both moisture and heavy hydrocarbons need to be removed, PSB can combine the two functions in a multi-layered-bed design. This approach can reduce capital costs and equipment footprint while addressing gas-treatment requirements before liquefaction. PSB fabricates, assembles and tests its systems at its 350,000-square-foot facility in Erie, Pennsylvania, helping control project cost, schedule and risk.
To discuss your LNG feed-gas conditions and dehydration or heavy hydrocarbon removal requirements, contact PSB Industries.